* Protection of an operator and environment from airborne infection when working with pathogenic groups.
* Protection of the work agents inside the work chamber from external contamination.
* If connected to the individual active exhaust system, cabinet can be used for work toxic chemical substances and radio nuclides in low quantities and for odor removal from the work agents.
* Cabinet is designed to equip workstations in the medical, pharmaceuticals and other institutes working with microorganisms of I-II-III-IV pathogenic groups and with parasitic disease agents.
* The work chamber is made of AISI 304 stainless steel.
* Front sash can be lifted for equipment loading. It is made of triplex and is supplied with two glove ports. Sash is resistant to UV-light and disinfectant solutions.
* Each glove port is equipped with a butyl chamber glove and a silicon sealing O-ring. Features of the gloves: high impermeability (water, gas, vapor), used at wide temperature range, resistant to solvents and high concentration acids, used for medical, pharmaceuticals, chemical and biotechnological research.
* Ten-liter liquid gathering tray without drain made of AISI stainless steel is located in the bottom of the work chamber.
* Two work chamber LED lighting units.
* Removable electrical sockets in the work chamber (on the left side wall).
* UV light inside the chamber.
* Filtering system of the air supplied to the chamber has two steps: preliminary coarse filter G4 and plenum HEPA filter H14 located above the work chamber.
* Two step filtering system of the air exhausted form the work chamber is executed through two consecutive HEPA filter H14.
* Supply and exhaust filtering module for removal of the air from the chamber is supplied with the two fans.
* Outer panel of the pass box are made of metal covered with powder enamel/ stainless steel.
* Inner chamber is leak - tight and mad of AISI 304 stainless steel.
* Windows of the pass box are made of tempered glass.
* LED Lighting of the pass box.
* UV light.
* Pull out tray made of AISI 304 stainless steel ensuring easy transferring of the objects form the pass box into hte work chamber.
* Microprocessor control system of the electroautomatics.
* Built in power cord.
* Switch for removable sockets unit installed in the work chamber.
For particles of 5.0 um and more | ISO 5, ISO M (20,=5 UM), LSAPC |
Cabinet class according to EN 12469, NSF/ANSI 49 | III |
Cabinet of the installed HEPA filters according to the EN 1822-1 | H 14 |
Pre-filter class according to EN 779 | G4 |
Minimal negative pressure in the working chamber, pa not less than | 200 |
Air inflow filtering Air outflow filtering | Two stage (G4, H14) Two stage (H14, H14) |
Air recirculation rate in the cabinet, % | No recirculation |
Cat No. | KMS-11001 | KMS-11002 |
Dimensions | 1219.2 x 609.6 x 609.6 mm | 1828.8 x 609.6 x 609.6 mm |
Power Consumption | 420 W | |
Maximum input power | 1420 W | |
HEPA filer | 270-320 m3/h |